“36 | Canby Utility SD-26-10 Clackamas Jeff Hampton / Matt Celentano 18,754 | | Issue: The Molalla River doesn’t currently meet available volumes above the treatment plants 8 MGD capacity. The current treatment plant also cannot treat for cyanotoxins or taste & odor problems associated with...”
Read the official document

Opens the publisher’s record in a new tab. The passage is an extract; use the original document for the surrounding context.

Saved excerpt and document details

The full captured excerpt is preserved below, including any partial sentences at its boundaries.

36 | Canby Utility SD-26-10 Clackamas Jeff Hampton / Matt Celentano 18,754 | | Issue: The Molalla River doesn’t currently meet available volumes above the treatment plants 8 MGD capacity. The current treatment plant also cannot treat for cyanotoxins or taste & odor problems associated with geosmin and MIB. The treatment plant is also not seismic ready. Project: New intake on Willamette River with greater capacity (up to 20.9MGD). New 17 MGD WTP: flocculation, ozone, filtration, chlorination. New finished water clearwell, pumping station, transmission main connected to existing distribution system. | | | | | Treatment Engineering | 9615000 | 400000 | Project is included on the 2026 IIJA Emerging Contaminants Funding Project Priority List (PPL) and is eligible for up to 100% principal forgiveness under that funding program. | Project is included on the 2026 IIJA Emerging Contaminants Funding Project Priority List (PPL) and is eligible for up to 100% principal forgiveness under that funding program. | Project is included on the 2026 IIJA Emerging Contaminants Funding Project Priority List (PPL) and is eligible for up to 100% principal forgiveness under that funding program. | No | 2026 (LOI expires on TBD) | 3Q2026 | 5 | Rating results include: 5 pts (Health Risk) due to proposed new treatment plant to mitigate potential cyanotoxins and taste & odor issues. 0 pts (Compliance) 0 pts (Consolidation) 0 pts (Affordability) 0 pts (Water System Size)